Ocular ultrasound: what it evaluates, types (A-mode and B-mode), and when it is indicated
Ocular ultrasound allows visualization of the interior of the eye when transparent structures are opaque—essential in cases of dense cataracts, vitreous hemorrhage, retinal detachment, and intraocular tumors
Ocular ultrasoundOcular ultrasoundOphthalmic A-mode and B-modeOcular ultrasoundOphthalmology Colombia 2026
👁️
GSMED Imaging medical team—diagnostic ultrasound Colombia
Based on: AAO (American Academy of Ophthalmology)—Ultrasound in Ophthalmology 2025, MSD Manual Professional (ocular ultrasonography), Moorfields Eye Hospital clinical protocols, and Clínica de Ojos Colombia.
May 2026AAO 2025 · MSD · Moorfields · Colombia
ℹ️ Medical content: Ocular ultrasound must be performed and interpreted by ophthalmologists or ultrasound technicians specializing in ophthalmology. This guide is for informational purposes.
The human eye is largely transparent—which is normally an advantage for vision but a problem when an opacity prevents the ophthalmologist from seeing the fundus. Ocular ultrasound addresses exactly this problem: it uses ultrasound to "see through" cataracts, vitreous hemorrhage, or any other opacity and evaluate the posterior structures of the eye.
1. Why the eye is ideal for ultrasound
The eye has anatomical features that make it perfectly suited for ultrasound: it is a small, superficial structure filled with liquid media (aqueous humor, vitreous humor) that transmit ultrasound perfectly, and surrounded by structures with different acoustic densities (cornea, lens, retina, sclera). These differences in density generate very clear echoes that the ultrasound machine converts into high-resolution images.
10 MHz
Typical frequency in ocular ultrasound—higher than in abdominal ultrasound for greater resolution
B-mode
The most commonly used modality—real-time two-dimensional imaging of the interior of the eye
0
Absolute contraindications for ocular ultrasound—completely safe
Gel
Applied over the closed eyelid—no contact with the eyeball is required
2. A-mode vs. B-mode—the two types of ocular ultrasound
📊
A-mode (axial)
Produces a one-dimensional representation (time/amplitude)—echoes are displayed as peaks of varying heights on a line. It does not produce a 2D image of the eye but rather a graph of reflections. Its main use in ophthalmology is ocular biometry: accurately measuring the axial length of the eye to calculate the power of the intraocular lens (IOL) before cataract surgery. Accuracy is measured in tenths of a millimeter—essential for post-surgical visual outcomes.
→ Pre-cataract biometry · IOL calculation · Axial length
🖼️
B-mode (two-dimensional)
Produces a real-time 2D image of the interior of the eye—the same principle as abdominal ultrasound but with higher frequencies (8–10 MHz) for greater resolution of small structures. It is the diagnostic mode for posterior segment evaluation: vitreous, retina, choroid, and sclera. It can detect retinal detachment, vitreous hemorrhage, intraocular tumors, and foreign bodies.
→ Posterior segment diagnosis · Retina · Vitreous · Tumors
3. When ocular ultrasound is indicated
| Indication |
Modality |
What the doctor is looking for |
| Dense cataract with no visible fundus |
B-mode |
Rule out retinal detachment, intraocular mass, or vitreous hemorrhage before cataract surgery |
| Vitreous hemorrhage |
B-mode |
Evaluate the condition of the underlying retina—if there is associated retinal detachment, urgent surgery is required |
| Suspected retinal detachment |
B-mode
Confirm the diagnosis and evaluate the extent, the presence of vitreoretinal traction, and the mobility of the retinal detachment |
| Suspected intraocular mass (melanoma, retinoblastoma) |
B-mode + color Doppler
Characterize the mass: size, shape, echogenicity, and internal vascularization on Doppler—guide the differential diagnosis |
| Pre-cataract surgery IOL calculation |
A-mode (biometry)
Axial length of the eye to calculate the power of the intraocular lens using formulas (SRK/T, Haigis, Barrett) |
| Ocular trauma—suspected intraocular foreign body |
B-mode
Locate the foreign body and evaluate associated damage (hemorrhage, detachment) |
| Acute angle-closure glaucoma |
UBM (ultrasound biomicroscopy)
Evaluate the anterior chamber angle, ciliary body, and lens with 20–50 MHz resolution |
4. How ocular ultrasound is performed
The standard technique for B-mode ocular ultrasound involves applying ultrasound gel over the patient's closed eyelid and sliding the transducer over it—without direct contact with the eyeball. The patient is comfortably reclined with their eyes closed. The exam takes 10–20 minutes. It does not cause pain or significant discomfort.
For ocular biometry (A-mode), topical anesthesia (anesthetic eye drops) is applied, and the transducer is gently placed in direct contact with the cornea—the same technique used in applanation tonometry. It takes 5–10 minutes.
Ultrasound biomicroscopy (UBM)—high-frequency ultrasound for the anterior segment UBM uses frequencies of 20–50 MHz—much higher than conventional ocular ultrasound—to generate extremely high-resolution images of the anterior segment of the eye: anterior chamber angle, ciliary body, iris, and lens. It is the reference tool for studying narrow-angle glaucoma, ciliary body cysts, and pigment dispersion syndrome. It requires immersion in liquid (an immersion cup filled with saline or methylcellulose) and topical anesthesia.
5. Frequently asked questions
Is ocular ultrasound painful?
No. The closed-eyelid technique (the most commonly used for B-mode) does not cause any pain or discomfort—the gel is applied over the closed eyelid, and the transducer is gently slid over it. A-mode biometry with corneal contact may cause a slight sensation of pressure—comparable to applanation tonometry—that disappears in seconds. UBM requires topical anesthesia and an immersion cup, which may be somewhat uncomfortable but not painful.
How much does ocular ultrasound cost in Colombia?
In the EPS system, ocular ultrasound (B-mode) is covered by the PBS when ordered by the treating ophthalmologist for a justified clinical indication. In the private sector, a B-mode ocular ultrasound can cost between $80,000 and $180,000 COP per eye. Ocular biometry for cataract surgery (A-mode) ranges from $60,000 to $150,000 COP. Anterior segment UBM is more expensive—between $150,000 and $350,000 COP—due to the specialized technology required.
Do I need any special preparation for ocular ultrasound?
No special preparation is required. You do not need to fast, you do not need to remove contact lenses (the gel is applied over the closed eyelid in the standard technique), and there are no prior activity restrictions. If the ultrasound will be performed using the immersion technique (UBM), the doctor will tell you not to use eye drops in the hours before the study. Wear comfortable clothes and, if possible, do not wear eye makeup.
High-frequency ultrasound machines for ophthalmology available in Colombia
10–15 MHz linear transducers with color Doppler—ideal for diagnostic B-mode ocular ultrasound.
Request information →
Ultrasound machines for ocular ultrasound and ophthalmology in Colombia
VINNO equipment with a high-frequency linear transducer and color Doppler—local GSMED technical support.
View ultrasound machines →