Liver Ultrasound: What It Evaluates, Preparation, and Findings

Ecografía Hepática_Qué Evalúa, Preparación y Hallazgos
Ultrasound and Ultrasonography

Liver Ultrasound: What It Evaluates, How to Prepare and What Findings It Detects

Everything you need to know about liver ultrasound: preparation, normal values, fatty liver, cirrhosis and other pathologies detected by ultrasound.

Reviewed by diagnostic imaging specialists · GSMED Imaging Colombia

The liver is the largest solid organ in the human body and one of the most frequently evaluated in internal medicine, gastroenterology and hepatology. Liver ultrasound —or liver ultrasonography— is the imaging technique of choice for its study: it does not use ionizing radiation, it is accessible, fast and allows real-time evaluation of the echostructure, size, hepatic vessels and the presence of focal or diffuse lesions.

In Colombia, liver ultrasound is one of the most requested studies in primary and secondary care. With current high-resolution equipment, ultrasound detects everything from mild hepatic steatosis to masses of just a few millimeters and evaluates portal vascular flow, elements that previously required computed tomography or magnetic resonance imaging.

What does liver ultrasound evaluate?

A complete liver ultrasound protocol includes the systematic evaluation of the following elements:

Size and morphology

Dimensions of the right and left lobes, liver borders (smooth or nodular) and overall shape.

Parenchymal echostructure

Homogeneity and echogenicity compared to the right renal cortex and the spleen.

Hepatic and portal veins

Caliber, patency and flow direction of the portal vein, suprahepatic veins and inferior vena cava.

Biliary tract

Common bile duct and intrahepatic duct caliber; dilation suggestive of biliary obstruction.

Gallbladder

Size, walls, presence of stones, biliary sludge or gallbladder polyps.

Focal lesions

Cysts, hemangiomas, solid nodules, metastases or abscesses within the liver parenchyma.

Preparation: fasting and other instructions

Preparation for liver ultrasound is stricter than for renal ultrasound, because intestinal gas and gastric contents can obscure the visualization of the liver, gallbladder and biliary tract.

⚠️ Main requirement: Fasting for 4 to 6 hours

Fasting is mandatory so that the gallbladder is distended (filled with bile) and can be properly assessed, and to reduce intestinal gas that interferes with the acoustic window. Without fasting, the gallbladder may be contracted and the image of the liver may be compromised.

✅
Water allowed

Water alone can be taken in small amounts. Some protocols allow up to 200 ml of water up to 2 hours before.

❌
Do not smoke before the exam

Smoking generates gas and stimulates secretions that make the image difficult. Avoid at least 4 hours before.

❌
Avoid flatulent foods

The night before, avoid legumes, carbonated drinks, cabbage and other foods that produce intestinal gas.

📋
Bring previous exams

Previous ultrasounds, transaminase results, bilirubin and any previous abdominal imaging study.

💡 Tip for diabetic patients: If the patient requires insulin or hypoglycemic medications, they should consult their doctor before the exam. In some cases, a very light breakfast (fat-free toast) is allowed to avoid hypoglycemia, partially sacrificing the visualization of the gallbladder. The radiologist must know this at the beginning of the study.

Normal liver values on ultrasound

The following parameters are the reference for adults in normal conditions:

Parameter Normal value (adult) Meaning if altered
Right lobe length 10 – 15 cm >15 cm: hepatomegaly; <10 cm: small liver (advanced cirrhosis)
Echogenicity Equal or slightly higher than the renal cortex Diffuse hyperechoic: fatty liver; diffuse hypoechoic: acute hepatitis
Portal vein (diameter) < 13 mm >13 mm: portal hypertension (cirrhosis, thrombosis)
Suprahepatic veins Visible, caliber < 10 mm Dilated: right heart failure; not visible: nodular cirrhosis
Common bile duct (main biliary tract) < 6 mm (without cholecystectomy) >6 mm suggests biliary tract dilation; >8 mm in cholecystectomized patients is normal
Gallbladder (wall) < 3 mm while fasting >3 mm: cholecystitis, hypoalbuminemia edema, hepatitis

* Reference values for adults according to standard abdominal radiology protocols (ACR, EFSUMB). They may vary according to body constitution and technique.

Common pathological findings

🟡 Hepatic steatosis (fatty liver)

It is the most frequent finding in liver ultrasound in Colombia, associated with obesity, type 2 diabetes, dyslipidemia and alcohol consumption. Fatty liver manifests as a diffuse increase in the echogenicity of the liver parenchyma.

Grade I (mild)

Slight increase in echogenicity. Hepatic vessels still visible.

Grade II (moderate)

Marked echogenicity. Hepatic vessels with blurred borders.

Grade III (severe)

Very high echogenicity. Vessels and diaphragm barely visible.

🔵 Simple liver cysts

They are very common benign lesions (prevalence 2–5 % of the population). They appear as anechoic images (completely dark), with thin and regular walls, with posterior acoustic enhancement. They do not require treatment or follow-up if they are truly simple and asymptomatic.

🔴 Hepatic hemangioma

It is the most common benign liver tumor. It appears as a well-defined hyperechoic mass (brighter than the parenchyma), generally small (<3 cm). For atypical or larger lesions, contrast-enhanced MRI is used for confirmation. Surgery is not required unless complications occur.

🟤 Liver cirrhosis

Ultrasound allows for the recognition of the classic signs of advanced cirrhosis:

  • • Nodular or irregular liver surface
  • • Heterogeneous parenchyma with increased echogenicity
  • • Caudate lobe hypertrophy and right lobe atrophy
  • • Signs of portal hypertension: dilated portal vein (>13 mm), splenomegaly, ascites
  • • Reversed (hepatofugal) portal flow on Doppler

⚫ Liver metastases

Metastases are the most common cause of malignant liver lesions. On ultrasound, they appear as nodules of variable echogenicity (hypoechoic, hyperechoic, or mixed), frequently multiple. Ultrasound is useful for initial detection; accurate staging requires contrast-enhanced CT or MRI.

🟢 Liver abscess

It presents as a hypoechoic or mixed collection, with irregular walls and possible internal septations. Ultrasound guides the diagnosis and can be used for ultrasound-guided percutaneous drainage. Amebic abscess (Entamoeba histolytica) is more common in Colombia than in industrialized countries.

CEUS: ultrasound contrast for liver lesion characterization

Contrast ultrasound (CEUS, from the English Contrast-Enhanced Ultrasound) uses intravenous gas microbubbles to evaluate the vascularization of liver lesions in real time, without radiation and without the nephrotoxicity of CT iodinated contrast.

What is liver CEUS used for?

  • ✓ Differentiate hemangioma from hepatocellular carcinoma
  • ✓ Characterize indeterminate nodules in cirrhosis
  • ✓ Guide biopsies and tumor ablations
  • ✓ Evaluate tumor treatment response

Advantages over contrast-enhanced CT

  • ✓ No ionizing radiation
  • ✓ No risk of nephrotoxicity
  • ✓ Dynamic real-time evaluation
  • ✓ Possible in patients with CKD or iodine allergy

High-end Mindray equipment available in Colombia includes an integrated CEUS module, allowing this type of advanced study without the need for CT or MRI in many cases.

Liver elastography: an alternative to FibroScan

Liver elastography is an ultrasound technique that measures the stiffness of the liver parenchyma, an indirect marker of the degree of fibrosis. The stiffer the liver, the greater the degree of fibrosis.

SWE / pSWE (Shear Wave Elastography)

Integrated into mid-to-high-end conventional ultrasound machines. It generates shear waves and measures the propagation speed to calculate stiffness in kPa. Equivalent to FibroScan in many contexts, with the advantage of being performed on the same ultrasound machine during the liver study.

Indicative stiffness values (kPa)

  • ● <5 kPa: normal liver (F0)
  • ● 5–7 kPa: mild fibrosis (F1–F2)
  • ● 7–10 kPa: significant fibrosis (F2–F3)
  • ● >12.5 kPa: probable cirrhosis (F4)

Elastography is especially useful in the follow-up of patients with chronic hepatitis B or C, alcoholic liver disease, or non-alcoholic steatohepatitis (NASH/MASLD), avoiding repeated liver biopsies.

Frequently asked questions about liver ultrasound

We answer the most common questions from patients and doctors.

How many hours of fasting are needed for a liver ultrasound?

The standard is 4 to 6 hours of fasting. Some protocols require 8 hours if the gallbladder and biliary tract are also evaluated. Water alone can be consumed in small amounts. Fasting allows the gallbladder to be distended and reduces intestinal gas that could interfere with the images.

Can ultrasound detect grade 1 fatty liver?

Ultrasound has good sensitivity for moderate and severe steatosis (grades II and III), but may have limitations in detecting mild grade I, especially in obese patients. In these cases, MRI with specific sequences (MRI-PDFF) is more sensitive for quantifying liver fat content.

What is the difference between liver ultrasound and abdominal CT?

Ultrasound does not use radiation, is faster, and is more accessible for the initial study. Contrast-enhanced CT offers greater anatomical detail, better evaluation of lesions smaller than 1 cm, and better oncological staging. They are complementary: ultrasound detects the problem; CT or MRI characterizes it in detail when necessary.

What precaution should diabetic patients take before the exam?

Insulin-dependent patients or those taking hypoglycemic medications should consult their doctor before the exam to adjust the dose. In some cases, a very light breakfast (fat-free toast, without protein) is allowed to prevent hypoglycemia, informing the radiologist at the start of the study. Never discontinue insulin without medical indication.

Can a liver ultrasound be done without fasting in the emergency room?

Yes. In emergency contexts (abdominal trauma, suspected acute cholecystitis, abscess, hemoperitoneum), the study is performed without fasting. Image quality may be limited, especially for the gallbladder, but the diagnostic benefit outweighs that limitation. The sonographer will adapt the protocol to the patient's condition.